Sardarni Manjit Kaur Auditorium

 

 

The modern auditorium with a seating capacity of 1500 is available for our academic related functions. Our auditorium is very comfortable and wide aisles enable patrons to remain seated as others pass by. Seating is terraced and staggered giving clear sightlines. Acoustics are good throughout the theatre. Air-conditioning helps keep theatre patrons in comfortable temperatures throughout the year.

 

 

 











 

SPACE ATTRIBUTES

 

Auditorium spaces are designed to accommodate large audiences. As such, they tend to have wide spans and are multiple-stories high in order to accommodate seating, sightline, and acoustical requirements. Raised stage/dais floors and special lighting equipment are often required as well. Typical features of Auditorium space types include the list of applicable design objectives elements as outlined below. For a complete list and definitions of the design objectives within the context of whole building design, click on the titles below.

 

Functional / Operational

 

  • Sloped Floors: Sloped floors, with level terraces for each row of seating, help provide the proper sightlines from the audience to the stage. Note that the bottom and intermediate rows should be directly accessible from entry levels to allow accessible seating positions.
  • Fixed Seats: Typically, fixed seats with tilting upholstered seat and back, integral arm and tablet arm are provided with articulated back for maximum occupant passage space between rows. The seats may be fully upholstered or wood contoured outer back and seat shells with wood armrests with tablet arm option and aisle light option at row ends.
  • Special Lighting: Dramatic lighting systems include front lighting, foot lighting, spot lights, follow spot lights, beam lights, and flood lights, and a projection room/booth with manual and programmable lighting controls, and space for the spot light operator space. Lighting systems should be flexible to accommodate various performance venues (e.g., lectures, plays, musical performances, etc.) in the Auditorium.
  • Occupancy: Seating is terraced and staggered giving clear sightlines. Acoustics are good throughout the theatre. Air-conditioning helps keep theatre patrons in comfortable temperatures throughout the year.

 

Productive

 

  • Special Acoustical Design: Quality acoustical characteristics are important in Auditorium spaces so that performances and presentations can be clearly heard and understood.

 

Sustainable

 

  • Increased Cooling Capacity: Heating, ventilating, and air-conditioning (HVAC) systems for Auditorium spaces are sized and zoned to accommodate varying internal loads, which are a function of audience sizes, performance lighting loads, and projection equipment. Particularly, air handling units (AHUs) with increased cooling capacity should be zoned separately for the auditorium, lobby, projection spaces, stage areas, and audience seating areas. Also, the Auditorium typically has a separate AHU constant volume with modulated temperature control for ventilation.
  • Raised Floor: The recommended system for distribution of HVAC in auditorium spaces is ducted supply through floor vents with ducted ceiling return air vents in auditorium and lobby. In other spaces, ducted ceiling supply with return air ceiling plenum is recommended. Note that there should be transfer ducts at all acoustically rated partitions
  •  

Secure / Safe

 

  • Fire and Life Safety: Proper notification systems, lighting, and signage are required to facilitate safe and speedy evacuations during an emergency in the Auditorium spaces. Step lights recessed into floor risers at each seating tier and wall mounted low light level sconce lights along side walls are typical. Sprinklers should be provided per code and under stage platforms to suppress fires.

 

 

 

 

   